- Download 3m Attest Auto Reader Operator Manual Free Download
- 3M Attest Rapid Readout
- 3M Attest Auto-Reader 390
Enter here:::.
Download 3m Attest Auto Reader Operator Manual Free Download
Xf maya 2013 x64 keygens. Product Description Designed to provide an optimal, stable growing environment for cultures. Interior capacity. Ideal for cell biology, viral growth, tissue culture, genetics studies, cancer research, embryo growth and microbiological/biochemical assays. Thermal conductivity CO2 sensor provides accurate CO2 control for applications with more consistent temperature and humidity levels. CO2 specifications: range: 0 to 20% control sensitivity: 0.1% stability: ±0.1% CO2 auto shut-off upon door opening.
Situs download video naruto shippuden terlengkap. Factory calibrated at 5 and 10%. Temperature specifications: range: 5°C above ambient to 60°C control sensitivity: ±0.1°C uniformity: ±0.4°C at 37°C. Factory calibrated at 37°C.
A water-jacket surrounds interior chamber for thermal stability and uniform heating. Features include an audible/visual CO2 alarm programmable for high/low deviation from setpoint, CO2 auto shut-off and a CO2 test port in center of glass door.
Temperature indicators include water-jacket temperature indicator and audible/visual programmable temperature alerts on high/low deviation from setpoint. Tempered inner glass door is heated by outer door to prevent condensation. Quick response and recovery after door openings. Has a 1.5' porthole in the rear wall with silicone stopper, adjustable levelling feet, closed-cell silicone inner door gasket that maintains a positive seal and water-jacket drain. Comes with a gas input HEPA filter.
Optional in-chamber HEPA filter removes 99.97% of airborne particulates such as hair, pollen, plant spores, skin and bacteria to dramatically improve air quality and provide additional protection from contamination. Maintains still air culture environment without high-velocity airflow (any filters that are with the chamber are not guaranteed) - Reversible inner and outer doors allow left-to-right or right-to-left opening. Control panel key switch for protection against unauthorized access. RS485 data port.
Remote alarm contacts. Battery back-up for alarm system. Autoclavable water pan helps to manage humidity, the primary factor in preventing cell and media desiccation. Includes 2 perforated, removable stainless steel shelves. Expandable to 20 shelves. The following link provides additional information from the instruction manual or original manufacturer's brochure. Images, specifications and description refer to the item as it was when new.
Right-click to open the PDF in a new window or download it. Chromatographs, calorimeters, evaporators, fluorometers, hydrogenators, osmometers, polarimeters, spectrophotometers, titrators, meters for pH / conductivity / dissolved solids / ORP. And much more. Bioreactors, cell disrupters, cell harvesters, cryostats, digesters, freeze-dryers / lyophilizers, growth chambers, homogenizers, hybridization, incubators, microscopes, osmometers, spiral platers, sterilizers. And much more. Balances, baths, blenders, centrifuges, chart recorders, freezers, fume hoods, furnaces, glassware washers, glove boxes, mixers, moisture testing, ovens, pumps, shakers, vacuum equipment, water purification.
And much more. Anaerobic incubators, autoclaves, blood testing, cell counters, CO2 incubators, cryostats, electrolyte analyzers, electrophoresis, glove boxes, microtomes, sterilizers. And much more.
3M Attest Rapid Readout
Baths, calorimeters, color measurement, density meters, flash point, hydrogenators, oil testing, penetrometers, surface tension, vapor pressure, viscometers and rheometers. And much more. Stability chambers, tablet disintegration, tablet dissolution, tablet hardness, V-blenders.
And much more. Abrasion, color measurement, environmental chambers, gloss / reflectance, hardness, impact testers, melt point, particle size, paint testers, penetrometers, sieve shakers, tensile strength, viscometers.
And much more.
Subjecting a chemical indicator to a sterilization process, the chemical indicator comprising: i) a substrate having a surface, and ii) sterilizing agent sensitive indicia associated with said surface of said substrate, said indicia having: (a) a first state prior to being exposed to the sterilization process, and (b) a second state after being exposed to said sterilization process, wherein the first state is different than said second state, and at least said second state is machine readable; and. THEN “REJECT” or “INADEQUATE” Yet another embodiment includes the step of integrating the relative intensities over a range of wavelengths surrounding the initial and final colors instead of using two discrete wavelength values.
Other mathematical correlations of these parameters could be used to maximize sensitivity and increase the safety margin. The threshold values (a) and (b) can be arrived at by using information taken from reference indicators subjected to a sterilization cycle known to be adequate or marginally adequate. By implementing an algorithm that is based on the percentage of a discrete or range of wavelengths, it is possible to include the option of a self-calibrating reader. This is made possible both by means of the earlier algorithms, which use relative changes instead of absolute changes in relative intensities, and by means of appropriate logic programming and memory.
The self-calibrating reader would initially read the indicator absorbance over the band of the visible spectrum. By logic circuitry, the reader would establish its own baseline and determine the wavelength, or range thereof, that has the greatest absorbance. From a group of spectra stored in its reference memory, it could be programmed to determine which type of sterilization indicator it was viewing (e.g. A steam chemical indicator, an ethylene oxide chemical indicator or models thereof).
For instance, if the reader found that the maximum absorbance of the chemical indicator was in the range of 760 nm, the reader itself would be able to determine that this represents a certain purple indicator that is sensitive to hydrogen peroxide. The reader can also read from memory that this indicator should finally achieve a spectrum that shows an absorbance at 495 nm—along with a value of relative change of both relative intensities. If a color standard were also employed, the reader could determine its own life cycle. That is, as it notes that a relative intensity for the standard has shifted (due to bulb fatigue, scratches on optics, weak battery, etc.), it can make the corresponding shifts in its logic to compensate for the changes. If the memory contained spectra of multiple stages of each sterilization cycle, it would also be able to establish which parameters have not been met. Additionally, it may also be able to quantify how far from adequate the parameters are as well. The present invention has now been described with reference to several embodiments and examples thereof.
It will be apparent to those skilled in the art that many changes or additions can be made in the embodiments described without departing from the scope of the present invention. Thus, the scope of the present invention should not be limited to the structures described in this application, but only by structures described by the language of the claims and the equivalents of those structures. Non-Patent Citations Reference 1 Addams, et al., Bar Coding: An Effective Productivity Concept, JONA, vol.
2 ANSI/AAMI ST45-1992 Bier/Steam Vessels. G., Cost Analysis of Three Low-Temperature Sterilization Systems, Journal of Healthcare Material Management, p. 4 European Standard Nos. EN867-1 and 866-1. 5 Good Hospital Practice: Steam Sterilization and Sterility Assurance, AAMI Recommended Practice, Section 6.4 (1988). 6 ISO 11140-1:1995.
7 Longe et al., Bar Code Technology in Health Care: A Tool for Enhancing Quality, Productivity, and Cost Management, Advanstar Communications, ISBN 0-929870-20-4, Library of Congress Catalog Card No. 93-71570 (1993). 8 Sterilization of Health Care Products-Chemical Indicators-Part 1: General Requirements, ANSI/AAMI ST60-(1966). 9 Sterilization of Health Care Products—Chemical Indicators—Part 1: General Requirements, ANSI/AAMI ST60-(1966). 10 The European Committee for Standardization's European Standard No. EN 867-1, Non-biological systems for use in sterilizers-Part 1: General Requirements.
11 The European Committee for Standardization's European Standard No. EN 867-1, Non-biological systems for use in sterilizers—Part 1: General Requirements. Patent application Ser. 09/368,742, Kirckof, filed Aug. Patent application Ser. 09/369,098, Kippenhan et al., filed Aug. Patent application Ser.
09/369,108, Hehenberger et al., filed Aug. Patent application Ser.
3M Attest Auto-Reader 390
09/369,410, Hehenberger et al., filed Aug. 16 Weilert et al., Putting Bar Codes to Work for Improved Patient Care, Clinics in Laboratory Medicine, vol.
Hi all, Due to a large new contract we will be branching out into areas new. As such a lot of info is required. Below is the beginning of a long long list of manuals that I am going to be looking for. Some of these may be duplicates etc but whatever you might have I would appreciate a copy.
Geoff's viewpoint and reasoning for the free exchange of service manuals is laudable, and though we differ in opinion I understand, and can respect his viewpoint. If you are in the business of wanting free service manuals, and then using that information for commercial gain, I would say your reasons for maintaining the flow of 'freeware' service manuals are less than philanthropic. 21/03/11 08:31 AM Re: Requests for Service Manuals Joined: Feb 2004 Posts: 13,164 Super Hero Super Hero Joined: Feb 2004 Posts: 13,164. Who then is to blame when it all goes wrong.? Slightly off topic, but in response to the post quoted from:- it seems that folk on here keep banging on about this, especially in relation to service contractors.
Whilst I can appreciate guys wanting to protect their own turf, can anybody actually cite a case where it has 'all gone wrong' due to the actions (or in-actions) of an outside service provider? - 21/03/11 08:57 AM Re: Requests for Service Manuals Joined: Jun 2009 Posts: 722 Philosopher Joined: Jun 2009 Posts: 722.